This is a product die-casting provided by the customer, and the customer needs to test its airtightness. This is a matching fixture we provide to the customer. We can connect it to our fixture through the communication line of the airtightness meter to achieve external control of the airtightness meter. Now, let me demonstrate for you.
189-1262-8676
This is a product die-casting provided by the customer, and the customer needs to test its airtightness. This is a matching fixture we provide to the customer. We can connect it to our fixture through the communication line of the airtightness meter to achieve external control of the airtightness meter. Now, let me demonstrate for you. First, we put the product into the fixture, and let's take a look at the parameter settings. The inflation time is 5 seconds, the equilibrium time is 10 seconds, the detection time is 5 seconds, the exhaust time is 1 second, and the inflation pressure is 7.5 kilopascals. We click on the function settings, check the grating allowance, and achieve a safety protection function of the grating. We return to the main page, double button start, and start the detection. The detection is completed, and the leakage amount is. 2.8 Pa